V6-CF Kiln Controller. The V6-CF is Bartlett Instrument Company's fifth. Features of the Model V6-CF Controller. This is covered in a separate KISS manual. Ceramic Clay, Pottery Accessories and Glass Kilns Equipment. Features of the Model V6- CF Controller. Firing Methods and Features which make firing easier: CONE FIRE METHOD - use when firing to a specific cone number using one of four speeds, "Slow Bisque", "Fast Bisque", "Slow Glaze", or "Fast Glaze". VARY- FIRE PROGRAMMER - Program up to 6 separate firing profiles for repeated use. Each profile may have up to 8 segments with separate heating or cooling rates, temperature set- points, and hold times. Use RECALL PROGRAM button to recall any firing program with one button ease. DELAY START - Delay the start of your firing up to 9. PREHEAT - Used with CONE FIRE method to hold a temperature of 2. В°F for a specified time prior to starting the firing. This can be used for drying ware. ALARM - User set audible temperature alarm. Advanced features: CONE OFFSET - Used to raise or lower the final temperature of any cone to fine tune the controller to your kiln. SKIP STEP - Skip from the present segment to the next ramp. The V6-CF is Bartlett Instrument Company's fifth generation kiln controller. Each generation has improved the reliability, features and ease-of-use to make Bartlett.V6-CF. $219.00. The V6-CF is Bartlett Instrument Company's fifth generation kiln controller. User Manual: Bartlett Instrument. Pyrometer Manual · Bartlett RTC-1000 Manual · Bartlett V6-CF Manual. Books. model, or if you Bartlett 3-Key Kiln Controller Electro Sitter, RTC-1000. . The Bartlett V6-CF Kiln Controller is the classis 12-key controller that. Brent Manual Clay. The V6-CF is Bartlett Instrument Company's fifth. Operation Manual Model V6-CF Controller BARTLETT INSTRUMENT COMPANY 1404 Avenue M Fort Madison, IA 52627 319-372-8366 WWW.BARTINST.COM. Bartlett Operation Manual for the Model V6-CF Controller : Bartlett Operation Manual for the Model V6-CF Controller |. Operation Manual Model V6-CF Series 700 Controller 1404 Avenue M Fort. The V6-CF controller eliminates much of the “babysitting” that is required with a. Shimpo/ ConeArt Kiln Options: V6-CF Bartlett Controller. The V6-CF controller is the. cone reaches maturity- perfect for manual kilns or as a. ERROR CODES - Error codes may be turned on so the kiln will automatically shut down if there is an error. They may be turned off for special firing profiles. SEGMENT PROGRAMS - User programs 5 and 6 can be combined for a 1. Messages and information: REVIEW PROGRAM - Review your firing profile any time before or during the firing. VIEW SEGMENT - View the current segment or skip to the next segment. CONE TABLE - Easily look up temperature and cone number equivalents. В°F or В°C - Choose between FARENHEIT or CELCIUS temperature scales. Communicates with personal computer equipped with KISS software. Programming. 1. CONE FIREThe CONE FIRE mode allows you to fire to a cone number with one of four different speeds. To use CONE FIRE: Make sure the temperature is flashing. Pressing the "1" key will clear the display of errors (Err) or FAIL. Press one of the 4 firing speed buttons (see Appendix A to see the ramp speeds)Slow Bisque - Used for setting a slow bisque firing profile. Fast Bisque - Used for setting a fast bisque firing profile. Slow Glaze - Used for setting a slow glaze firing profile. Fast Glaze - Used for setting a fast glaze firing profile. Press ENTER. Type the cone number you want (acceptable values are from . If you type a wrong number, press "0" 3 times or until all zeros appear in the display, press ENTER, then type the correct number (only three digits are displayed at this time)Press ENTER. Type the hold time at the end of the firing or leave at zero. Press ENTER. 'CPL' will be displayed briefly, then the current temperature will be flashing in the display. Press START/STOP to begin firing. NOTE: With any of the CONE FIRE modes, a preheat stage is available. During the preheat stage the temperature is increased at a rate of 6. В°F per hour until 2. В°F is reached; the 2. В° temperature is then held for the programmed amount of time. Preheat is automatically set to zero during cone fire programming and at the end of each firing, so if a preheat stage is wanted, it must be reprogrammed before each cone firing. See SECTION 4 - "OTHER" options for programming "Preheat". CONE FIRE Example. Slow Bisque Firing, Pre- heat 1 hour, Cone 0. Hold - Use the following steps for a bisque firing to cone 0. Step. Press. Display. Comment. 1Slow Bisque. S- b. CIf you press the wrong button, before pressing ENTER, simply press the correct button. ENTERalternately flashing: Con. E & No. Slow Bisque is now selected. The word Con. E and the last entered cone number will alternately flash on the display. Now enter the cone number - 0. Con. E & 0. 4The word Con. E and the entered cone number will alternately flash on the display. If you type a wrong number, press zero 4 times, then type the correct number. ENTERalternately flashing: HLd & 0. The cone number has been accepted. Now enter the 1. 0 minute hold time. Numbers to left of decimal point are hours, to the right of decimal point are minutes. If you type a wrong number, press zero 4 times, then type the correct number. ENTERCPL flashes, then the current temperature. The 1. 0 minute hold time is accepted. CPL indicates the firing profile has been completed. OTHER until Pr. Ht displayed. Pr. Ht. Press OTHER until Pr. Ht is displayed. If you accidentally pass Pr. Ht press "OTHER" several more times until Pr. Ht appears again. ENTERalternating flashing: HLd & 0. Preheat has been selected and the hold time is to be entered now. Numbers to left of decimal point are hours, to the right of decimal point are minutes. NOTE: For a 1 hour hold time you could also enter 6. If you type a wrong number, press zero 4 times, then type the correct number. ENTERCPL flashes, then current temperature. Accepts a hold time of 1 hour, then CPL indicates the preheat stage has been completed. START/STOP- On- After - On- is displayed for several seconds, the heating elements of the kiln will cycle on and the current temperature in the kiln will be displayed. If a time is displayed instead of the current temperature, then a delay start is in effect. If you do not want to delay the start press START/STOP button, then DELAY, then 0. ENTER. When the current temperature again flashes in the display, press START/STOP. VARY- FIREThe V6- CF has 6 vary- fire user programs to store and reuse. Each program has from 1 to 8 segments (2 - 1. Each segment has a firing rate, a soak temperature and a hold time. It is best to write out the firing profile that you plan to program before you begin programming. To ramp at the maximum rate either up or down, enter a rate of 9. To program a down ramp, you enter the rate/hour then a temperature below the previous segment temperature. NOTE: The first ramp rate of any user program. The following example is a two segment program stored in memory location "user 1". Segment. Rate В°F/hour. Temperature. Hold. NOTE: Appendix D of this user manual is a blank form for your firing programs. VARY- FIRE Example. The following steps are used to program "user 1" program for the firing profile above. Step. Press. Display. Comment. 1ENTER PROGalternately flashing: USEr & No. The display alternates between USEr and the last selected user number. Selects user (USEr) profile number 1. ENTERalternately flashing: SEG & No. The displays flashes between SEG and the number of segments which were previously programmed. This is the number of segments needed for our example. ENTERAlternately flashing: r. A 1 & No. The display flashes between r. A 1 and the heating rate per hour that was previously programmed. Displays the selected rate/hour. ENTERAlternately flashing: В°F 1 & No. The display flashes between В°F 1 & the temperature previously programmed. Displays the selected temperature. ENTERAlternately flashing: HLd. No. The display flashes between HLd 1 & the hours and minutes which were previously programmed. If display does not show 0. ENTERAlternately flashing: r. A 2 & No. The display flashes between r. A 2 & the heating rate previously programmed. Displays the selected rate/hour. ENTERAlternately flashing: В°F 2 & No. The display flashes between В°F 2 & the temperature which was previously programmed. Displays the selected temperature. ENTERAlternately flashing: HLd. No. The displays flashes between HLd. No hold time. 1. 7ENTERAlternately flashing: ALAr & No. The display alternates between ALAr & the previously used alarm setting. Enters the temperature at which the alarm will sound. The alarm will be turned OFF with a setting of 9. ENTERCPL flashes then the current temperature. CPL flashes several times indicating the program has been completed. The current temperature then flashes in the display. RECALL PROGRAM is used to recall a previously programmed firing profile. Example: To recall user program #5, use the following: Step. Press. Display. Comment. RECALL PROGAlternately flashing: USEr & 1. The controller is ready to accept the desired user number. Indicates the user program selected. ENTERCPL flashes then the current temperature. CPL flashes several times indicating the program has been selected. The current temperature then flashes in the display. VIEW SECTIONView Section - Contains buttons to look up Cone Temperatures, Review programs, View current segment and Skip segments during firings. The VIEW section allows you to view various information about cone temperatures, firings, and settings. Cone Table - Used to look up the temperature of various cone numbers. The temperature which is displayed is for self- supporting cones with a heating rate of 1. В°F/hr. TO use, press "Cone Table", enter the cone number you want to look up, press "ENTER"; the cone temperature will be displayed followed by CPL. Review Program - The information displayed when Review Program is pressed varies depending on whether you are using Cone Fire or Vary Fire. When Review Program is pressed, each of the steps in the current firing profile is displayed one after another changing every 1/2 second. In Cone Fire Mode - The display will show the selected firing profile in the following order: cone fire speedpreheat time (Pr. Ht)cone #(Con. E)cone temperature* (В°F)hold time (HLd)delay time (d. ELA)alarm setting (ALAr)error codes on/off (Er. Cd)LAG setting (if zone control)*After a firing is complete, the cone temperature (В°F) will show the actual temperature reached during firing. In Vary Fire Mode - The display will show in the following order: the user program # (USEr)the number of segments (SEG)1st ramp rate (r. A 1)1st segment temperature (В°F 1)1st hold time (HLd. If there is more than 1 segment, then the ramp rate, segment temperature, and hold time of each of the other segments will be displayed in order.)delay time (d. ELA)alarm setting (ALAr)error codes on/off (Er. Cd)LAG setting if zone control. View Segment - only functions when a firing is in progress. View segment is used to view the current firing segment or to skip from the current segment to the next firing ramp.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
March 2017
Categories |